Home Danmark
  Løsninger
Produkter
Support - Service
Nyheder
Udleje / Salg
Om os
Kontakt   Danmark
 
 

Leica Nivel200

Technical Data
 Measuring range
Range From 
[mrad]
-1.51
B -2.51
C -3.00 
  To   
[cc]  [mrad]  [cc] 
-960  +1.51  +960 
-1600 +2.51  +1600 
-1900 +3.00 +1900 
Resolution [mrad] 
0.001
[cc] 
0.6 
Zero-point-stability [mrad / °C]
0.00471
[cc / °C]
>3
Accuracy
Range [mrad]
+/-0.0047
B +/-0.0141
C +/-0.0471
[cc] 
+/-3 
+/-9
+/-30

 

 

 

 

 

 

 

 

Power supply voltage Nominal voltage 12 VDC
voltage range 9 -15 VDC
Power consumtion 0.6 W, 50 mA
Dimensions (LxWxH) approx. 95 x 91 x 68 mm
Weight 0.74 kg
Environmental Specifications

Working temperature -20 to +50 °C
Storing temperature -40 to +70 °C
Dust/water (IEC 60529) IP50
Humidity 95%, non-condensing 

Averaging function mean value can be calculated by sensor for up to 128 measurements
Sensor addressability max. 32 different addresses can be stored in sensor
Measuring cycle 300 ms
Temperature sensor Measuring range -20 to +50 °C
Interfaces Nivel210: RS232 serial port
Nivel220: RS485 serial port
Baud rates 1200, 2400, 9600, 19200, 38400